Specification of Gland Packing Chesterton 1622 Grafite (082177541310)

Chesterton 1622

Low E Control Packing for Block Valves

Chesterton 1622 Low E Packing is designed to minimize valve emissions

and it exceeds current emissions requirements for the refinery, petrochemical,

and chemical industries. 1622 has received both the National Pollution

Prevention Roundtable MVP2 and Vaaler Award for emission and pollution

reduction technology.

Guaranteed* to seal less than 100 ppm for 5 years per EPA method 21.

1622

Technical Data

Material Inconel® wire-reinforced, flexible graphite packing with special

blocking agents

Applications Light and heavy hydrocarbons, VOCs, VHAPs, steam, and most

non-oxidizing chemicals

Pressure Limit 345 bar g (5000 psig)

Temperature Limit Max 650°C (1200°F) steam, 450°C (850°F) oxidizing atmosphere

Chemical Resistance pH 0 – 14 except in strong oxidizers